Quick Disconnect Cord Sets
- Available in 6' and 12' lengths
- Three and four conductor available for single and three phase
- Type STOOW 16 gage cord with molded plugs
- Rated for 12 A, 600 VAC
- Supplied as a set: cord, receptacle and watertight fitting wired
to fan motor for specified voltage
|
 |
Junction Box with Cluster Cover
- Weatherproof die-cast aluminum junction box and cover. Three ¾"
outlets in box and three ½" outlets in the domed cover
- Accepts up to two receptacles (not included, order with Quick Disconnect
Cord Set)
- Reinforced connector outlets
State-of-the-art powder coat finish
Eight box mounting options with detachable lugs provided
Ground screw installed
Internal threads and hubs comply with NEMA requirements. Hubs accept
all threaded fittings and threaded conduit
- Cluster covers are supplied with two closure plugs
- UL 514-A listed, File E195978 / CSA C22.2 No. 18 / NEMA 3R Rated
|
 |
Plain End Cord Sets
- Available in any length
- Three and four conductor available for single and three phase
- Type STOOW 16 gage cord with molded plugs
- Supplied as a set: cord and watertight fitting wired to fan motor
for specified voltage
|
 |
Mounting Bracket Kits
- Hot dip galvanized for durability
- Choice of 24" or 8" flat bars
- 19" all thread rod for a variety of radiator thicknesses
|
 |
Foot Mount Adapter for CF Master
- Hot Dip galvanized welded construction
- NEMA 48 mounting hole pattern
- Holes for 1-1/2" U-bolts
|
 |
Top Oil Thermometer
- DIAL:
6" Diameter Polycarbonate Lens
0-160° C Range
± 2% of Full Scale Accuracy
- CAPILLARY:
12' Length with Braided Copper Armor
Sensing Bulb 5.81" long x 0.481" dia.
7/8"-14 Element Connection
Optional adapters are available to match threads in existing thermowell
- ELECTRICAL CONNECTION:
144'' 16 Ga. SO Cable
Water-tight Fitting
Color Coded
- SWITCHES - 3 x SPST
Original Settings: 65°C, 80°C, 105°C
(Can be reset in the field between 16°C - 144°C)
Rated 10 Amps @ 125/250VAC
- CASE:
Cast Aluminum
ASA #70 Gray Finish
Stainless Steel Bezel
View the Manufacturer's
Instructions for this item
|
 |
Control Box
- Can be configured to control any number of transformer cooling fans
- Single or two stage
- Three position switch: Manual - Off - Automatic
- NEMA 3R enclosure standard, other types available
- Compact DIN rail terminals standard, heavy duty barrier terminal
available
Download
Control Box Selection Form
|