Quick Disconnect Cord Sets
- Available in 6' and 12' lengths
- Three and four conductor available for single and three phase
- Type STOOW 16 gage cord with molded plugs
- Supplied as a set: cord, receptacle and watertight fitting
wired to fan motor for specified voltage
|
| |
Junction Box with Cluster Cover
- Weatherproof die-cast aluminum junction box and cover. Three
¾" outlets in box and three ½" outlets
in the domed cover
- Accepts up to two receptacles (not included, order with Quick
Disconnect Cord Set)
- Reinforced connector outlets
State-of-the-art powder coat finish
Eight box mounting options with detachable lugs provided
Ground screw installed
Internal threads and hubs comply with NEMA requirements. Hubs
accept all threaded fittings and threaded conduit
- Cluster covers are supplied with two closure plugs
- UL 514-A listed, File E195978 / CSA C22.2 No. 18 / NEMA 3R Rated
|
 |
Plain End Cord Sets
- Available in any length
- Three and four conductor available for single and three phase
- Type STOOW 16 gage cord with molded plugs
- Supplied as a set: cord and watertight fitting wired to fan
motor for specified voltage
|
 |
Mounting Bracket Kits
- Hot dip galvanized for durability
- Choice of 24" or 8" flat bars
- Kits available for a variety of radiator thicknesses
|
 |
Footmount Adapter for CF Master
- Welded Stainless Steel construction
- NEMA 48 mounting hole pattern
- Holes for 1-1/2" U-bolts
|
 |
Top Oil Thermometer
- 6" Diameter Face
- 0-160° C Range, ± 2% of Full Scale
- 12' Capillary Armored Tube with Thermowell
- 30'' Cable with Water-tight Fitting
- Three Field Adjustable Switches (rated: 10 Amps @ 125/250VAC)
- Switch Settings: 65°C, 80°C, 105°C
View
the Manufacturer's Instructions for this item
|
 |
Control Box
|
* Test Method: AMCA 210-99,
fig. 12/ ISO 5801, fig. 71b, fan installation type A, free inlet and
free outlet. Other impeller arrangements will affect the performance.
** Sound levels listed here were determined under laboratory conditions.
Many factors can influence fan sound levels that are beyond the control
of the propeller manufacturer or California Turbo, Inc; including
inlet geometry and obstructions in the airflow. Please use this information
for comparison purposes only.
NOTE: Electrical and noise data are supplied by the motor and propeller
manufacturers, respectively. These values have not been independently
verified by California Turbo, Inc.
California Turbo, Inc. reserves the right to make product changes
from time to time, without prior notification. |